Islanding is the condition in which a distributed generator (DG) continues to power a location even though external electrical grid power is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. Additionally, without strict frequency control, the balance between load and generation in the islanded circuit can be violated, thereby leading to abnormal frequencies and voltages. For those reasons, distributed generators must detect islanding and immediately disconnect from the circuit; this is referred to as anti-islanding.

AttributesValues
rdfs:label
  • انفصال عن الشبكة (ar)
  • Einrichtung zur Netzüberwachung mit zugeordneten Schaltorganen (de)
  • Islanding (en)
  • Îlotage (fr)
  • Острівкування (uk)
rdfs:comment
  • الانفصال عن الشبكة أو الاستقلال عن الشبكة حالة تشغيلية لمولد «في الموقع» يقدر فيها على تغذية شبكة مستقلة ومنفصلة تماما عن الشبكة الكهربائية الرئيسية. قد يصمم الجهاز لمجرد هذا الغرض ولا يستطيع التعامل مع الشبكة الرئيسية، أو قد يصمم للتعامل مع الحالتين التشغيلتين (المتصلة والمنفصلة كلاهما، ويسمى نظام هجين) بشرط أن يُعاد إبداء المولد، أو قد يصمم للانتقال بين الحالتين بسلاسة أيضا. تتطلب هذه الشبكات أصرم أنواع لأجل والمولدات، وإلا خرق التردد والجهد حدود المقبول. لذا عند سقوط الشبكة الرئيسية، يجب أن يستشعر أي مولد (متصل) أن اتصاله بالشبكة قد سقط. (ar)
  • Eine Einrichtung zur Netzüberwachung mit zugeordneten Schaltorganen (ENS) ist eine automatische Freischaltstelle für kleine Stromerzeugungsanlagen bis 30 kW Spitzenleistung. Sie garantiert, dass sich der Wechselrichter bei Stromausfall oder Netzabschaltung auf jeden Fall selbständig vom Stromnetz trennt, um eine Inselbildung und dadurch erfolgende Rückspeisungen in das Stromnetz zu verhindern, die möglicherweise zu gefährlichen Auswirkungen führen könnten. Erarbeitet wurden die Anforderungen an eine ENS von der Berufsgenossenschaft der Feinmechanik und Elektrotechnik, zusammen mit der VDEW-Projektgruppe „TAB für Kleinkraftwerke“. (de)
  • Islanding is the condition in which a distributed generator (DG) continues to power a location even though external electrical grid power is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. Additionally, without strict frequency control, the balance between load and generation in the islanded circuit can be violated, thereby leading to abnormal frequencies and voltages. For those reasons, distributed generators must detect islanding and immediately disconnect from the circuit; this is referred to as anti-islanding. (en)
  • En ingénierie nucléaire, un îlotage est un régime de fonctionnement d'un réacteur nucléaire. Il consiste à isoler le réacteur du réseau électrique externe, tout en le maintenant en puissance. Le réacteur ne produit via son alternateur que l'énergie électrique nécessaire à son fonctionnement tout en étant coupé du réseau électrique (ouverture du disjoncteur desservant la ligne principale). Par extension, l'îlotage désigne la transition vers ce régime de fonctionnement. Dans les centrales nucléaires françaises, des essais d’îlotage sont réalisés pour chaque réacteur tous les 4 ans. (fr)
  • Острівкув́ання – режим функціонування сегменту мережі, коли місцева генерація ізольованого сегменту електромережі або окремо взятий генератор продовжує виробляти електроенергію та живити від'єднаний сегмент мережі навіть коли відбулось від'єднання його від макромережі. За умисного острівкування генератор від'єднується від мережі і змушує розподілений генератор живити місцеву мережу. (uk)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • الانفصال عن الشبكة أو الاستقلال عن الشبكة حالة تشغيلية لمولد «في الموقع» يقدر فيها على تغذية شبكة مستقلة ومنفصلة تماما عن الشبكة الكهربائية الرئيسية. قد يصمم الجهاز لمجرد هذا الغرض ولا يستطيع التعامل مع الشبكة الرئيسية، أو قد يصمم للتعامل مع الحالتين التشغيلتين (المتصلة والمنفصلة كلاهما، ويسمى نظام هجين) بشرط أن يُعاد إبداء المولد، أو قد يصمم للانتقال بين الحالتين بسلاسة أيضا. تتطلب هذه الشبكات أصرم أنواع لأجل والمولدات، وإلا خرق التردد والجهد حدود المقبول. لذا عند سقوط الشبكة الرئيسية، يجب أن يستشعر أي مولد (متصل) أن اتصاله بالشبكة قد سقط. (ar)
  • Eine Einrichtung zur Netzüberwachung mit zugeordneten Schaltorganen (ENS) ist eine automatische Freischaltstelle für kleine Stromerzeugungsanlagen bis 30 kW Spitzenleistung. Sie garantiert, dass sich der Wechselrichter bei Stromausfall oder Netzabschaltung auf jeden Fall selbständig vom Stromnetz trennt, um eine Inselbildung und dadurch erfolgende Rückspeisungen in das Stromnetz zu verhindern, die möglicherweise zu gefährlichen Auswirkungen führen könnten. Erarbeitet wurden die Anforderungen an eine ENS von der Berufsgenossenschaft der Feinmechanik und Elektrotechnik, zusammen mit der VDEW-Projektgruppe „TAB für Kleinkraftwerke“. (de)
  • Islanding is the condition in which a distributed generator (DG) continues to power a location even though external electrical grid power is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. Additionally, without strict frequency control, the balance between load and generation in the islanded circuit can be violated, thereby leading to abnormal frequencies and voltages. For those reasons, distributed generators must detect islanding and immediately disconnect from the circuit; this is referred to as anti-islanding. Some designs, commonly known as a microgrid, allow for intentional islanding. In case of a power outage, a microgrid controller disconnects the local circuit from the grid on a dedicated switch and forces the distributed generator(s) to power the entire local load. A common example of intentional islanding is a distribution feeder that has solar panels attached to it. In the case of an outage, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the circuit detached by the outage becomes an "island". For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry. In nuclear power plants, islanding is an exceptional mode of operation of a nuclear reactor. In this mode, the power plant is disconnected from the grid, and power for cooling systems comes from the reactor itself. For some reactor types, islanding is part of the normal procedure when the power plant disconnects from the grid, in order to quickly recover electricity production. When islanding fails, emergency systems (such as diesel generators) take over. For instance, French nuclear power plants conduct islanding tests every four years. (en)
  • En ingénierie nucléaire, un îlotage est un régime de fonctionnement d'un réacteur nucléaire. Il consiste à isoler le réacteur du réseau électrique externe, tout en le maintenant en puissance. Le réacteur ne produit via son alternateur que l'énergie électrique nécessaire à son fonctionnement tout en étant coupé du réseau électrique (ouverture du disjoncteur desservant la ligne principale). Par extension, l'îlotage désigne la transition vers ce régime de fonctionnement. L'îlotage est un moyen de maintenir le réacteur dans un état sûr lors de défaillances du réseau électrique. Il permet d'assurer la sécurité du réacteur en cas de défaillance du réseau électrique, et de reprendre rapidement la production sur le réseau après un black-out. Le passage du régime normal de production à pleine puissance à l'état d'îlotage est le transitoire le plus important que peut subir l'installation. Il est susceptible de déclencher les protections turbine et réacteur. C'est pourquoi l'essai périodique d'îlotage, consistant à couper l'alimentation électrique principale à pleine puissance, permet de s'assurer du bon réglage des nombreuses chaînes de régulation de l'installation.Dans les centrales nucléaires françaises, l'échec de l'îlotage génère un arrêt automatique du réacteur par perte de l'alimentation des pompes primaires (qui assurent le refroidissement du cœur), et un basculement sur la source extérieure auxiliaire (225 kV) de l'alimentation de ses systèmes importants pour la sûreté. La puissance fournie par cette source auxiliaire ne permettant pas l'alimentation des pompes primaires, le refroidissement du cœur s'effectue alors par thermosiphon (c'est-à-dire par convection naturelle). Le redémarrage de l'installation ne pourra se produire que si l'alimentation extérieure principale est rétablie. On voit donc qu'en cas de défaillance du réseau extérieur, de la capacité des tranches à réussir l'îlotage dépendront les conséquences de cette défaillance : une fois supprimé le défaut à l'origine de la panne, le réseau sera rétabli à partir des tranches dont l'îlotage a réussi. L'essai d'îlotage est un élément fondamental de la sûreté du réseau. Dans les centrales nucléaires françaises, des essais d’îlotage sont réalisés pour chaque réacteur tous les 4 ans. L'accident de Tchernobyl du 26 avril 1986 s'est produit lors d'un essai d'îlotage. (fr)
  • Острівкув́ання – режим функціонування сегменту мережі, коли місцева генерація ізольованого сегменту електромережі або окремо взятий генератор продовжує виробляти електроенергію та живити від'єднаний сегмент мережі навіть коли відбулось від'єднання його від макромережі. Острівкування може бути небезпечним для працівників енергетичної станції та побутових споживачів, які можуть вчасно не зрозуміти, що від'єднаний сегмент мережі від основної мережі все ще під напругою, тому індивідуальні генератори та мікроінвертори мають визначати факт острівкування і зупинити подачу енергії — така функція називається «анти-острівкування» (англ. anti-islanding). Загальний приклад острівкування — мережа ліній поставки, що приєднані до сонячних панелей. У випадку відключення, сонячні батареї будуть продовжувати постачати енергію поки буде достатня освітленість. У випадку, коли лінії поставки стають енергетичними «острівцями», вони оточені «морем» знеструмлених ліній. З цієї причини, були створені сонячні інвертори, які розроблені таким чином, щоб постачати енергію до мережі, де зазвичай потрібна наявність деякої подоби схеми автоматичного анти-острівкування у них. За умисного острівкування генератор від'єднується від мережі і змушує розподілений генератор живити місцеву мережу. (uk)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (61 GB total memory, 51 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software