About: Fourier-transform ion cyclotron resonance     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : owl:Thing, within Data Space : dbpedia.org associated with source document(s)
QRcode icon
http://dbpedia.org/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FFourier-transform_ion_cyclotron_resonance

Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (m/z) of ions based on the cyclotron frequency of the ions in a fixed magnetic field. The ions are trapped in a Penning trap (a magnetic field with electric trapping plates), where they are excited (at their resonant cyclotron frequencies) to a larger cyclotron radius by an oscillating electric field orthogonal to the magnetic field. After the excitation field is removed, the ions are rotating at their cyclotron frequency in phase (as a "packet" of ions). These ions induce a charge (detected as an image current) on a pair of electrodes as the packets of ions pass close to them. The resulting signal is called a free induction decay (FID), tra

AttributesValues
rdfs:label
  • FT-ICR-Massenspektrometrie (de)
  • Espectrometría de resonancia ciclotrónica por transformada de Fourier (es)
  • Fourier-transform ion cyclotron resonance (en)
  • Analizzatore a risonanza ionica ciclotronica a trasformata di Fourier (it)
  • Spectrométrie de masse à résonance cyclonique ionique (fr)
  • フーリエ変換イオンサイクロトロン共鳴質量分析計 (ja)
  • Analizator cyklotronowego rezonansu jonów z fourierowską transformacją wyników (pl)
  • Масс-анализатор ионно-циклотронного резонанса с Фурье-преобразованием (ru)
  • 傅里叶变换离子回旋共振质谱法 (zh)
rdfs:comment
  • Die FT-ICR-Massenspektrometrie (FT-ICR-MS = Fourier-Transform Ionenzyklotronresonanz Massenspektrometrie) ist ein Verfahren der Ionenfallen-Massenspektrometrie mit sehr hoher Massenauflösung. (de)
  • In spettrometria di massa l'analizzatore a risonanza ionica ciclotronica a trasformata di Fourier è un analizzatore basato sul fatto che uno ione eccitato con radiofrequenze emette energia. Richiede un vuoto spinto, dell'ordine di 10-9-10-10 Torr. È un analizzatore non distruttivo, ha risoluzione fino a 1.000.000. Si indica comunemente come FT-ICR, acronimo dell'inglese Fourier transform-ion cyclotron resonance. (it)
  • フーリエ変換イオンサイクロトロン共鳴質量分析計(Fourier Transfom Ion Cyclotron Resonance Mass Spectrometer;FT-ICR-MS)とは、質量分析計の形式の一つ。 (ja)
  • Масс-анализатор ионно-циклотронного резонанса с Фурье-преобразованием (Fourier transfrom ion cyclotron resonance - FT/ICR MS, Fourier transform mass spectrometry) - тип масс-анализатора для определения отношения массы к заряду по циклотронной частоте иона в фиксированном магнитном поле. (ru)
  • Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (m/z) of ions based on the cyclotron frequency of the ions in a fixed magnetic field. The ions are trapped in a Penning trap (a magnetic field with electric trapping plates), where they are excited (at their resonant cyclotron frequencies) to a larger cyclotron radius by an oscillating electric field orthogonal to the magnetic field. After the excitation field is removed, the ions are rotating at their cyclotron frequency in phase (as a "packet" of ions). These ions induce a charge (detected as an image current) on a pair of electrodes as the packets of ions pass close to them. The resulting signal is called a free induction decay (FID), tra (en)
  • La espectrometría de masas por resonancia de ciclotrón iónica por transformada de Fourier (FT-ICR por sus siglas en inglés) es un tipo de analizador de masas (o espectrómetro de masas) para determinar la relación masa-carga (m/z) de iones en función de la frecuencia de ciclotrón de los iones en un campo magnético fijo.​ Los iones están atrapados en una trampa Penning (un campo magnético con placas de captura eléctricas), donde son excitados (en sus frecuencias de ciclotrón resonantes) a un radio de ciclotrón más grande por un campo eléctrico oscilante ortogonal al campo magnético. Después de que se elimina el campo de excitación, los iones giran en su frecuencia de ciclotrón en fase (como un "paquete" de iones). Estos iones inducen una carga (detectada como una corriente de imagen) en un p (es)
  • La spectrométrie de masse à résonance cyclotronique ionique (FT-ICR-MS) est un instrument possédant un haut pouvoir de résolution et une bonne exactitude sur la masse très important pour l’analyse des protéines. C’est une technique basée sur le piégeage et l’excitation des ions dans une cellule ICR (résonance cyclotronique des ions) sous l’action d’un champ électromagnétique. Le spectre de masse est obtenu via la transformée de Fourier qui convertit le signal temporel acquis en spectre de fréquence proportionnel à la masse. FT-ICR-MS a été développée pour la première fois par Comisarow et Marshall en 1974, et l’utilisation du principe d’ICR dans un spectre de masse par Sommer. Cette technique d’analyse est très appliquée dans le domaine pharmaceutique, biologique par exemple pour l’identif (fr)
  • Analizator cyklotronowego rezonansu jonów z fourierowską transformacją wyników (Fourier Transform Ion Cyclotron Resonance, FT-ICR) – analizator stosunku masy do ładunku elektrycznego jonów, jest głównym elementem konstrukcji niektórych spektrometrów mas. W pułapce analizatora poprzez odpowiednie wzbudzanie można selekcjonować jony, usuwać wybrane jony, chłodzić jony. (pl)
  • 傅里叶变换离子回旋共振质谱法也称作傅里叶变换质谱分析,这是一种根据给定磁场中的离子回旋频率来测量离子(m/z)的质谱分析方法。彭宁离子阱(Penning Trap)中的离子被垂直于磁场的震荡电场激发出一个更大的回旋半径,这种激发作用同时也会导致离子的同相移动(形成离子束)。当回旋的离子束接近一对捕集板时,捕集板上会检测到影像电流信号。这种信号被称为自由感应衰减(FID),是一种由许多重叠的正弦波组成的瞬态或干涉图。通过傅里叶变换,我们可以从这些信号数据中萃取出有用的信号形成质谱。 傅里叶变换离子回旋共振质谱法(FTICR-MS)具有非常高的析像能力,可以十分精确地测定物质。因此对于FTICR-MS的使用主要是利用它的高分辨率检测分子组成。这一检测的理论前提是元素在这一过程中会发生质量亏损。此外,FTICR-MS通常也被用来研究复杂的混合物。这是由于它所产生的分析图像具有较窄的峰宽,能够将两个质量相近的离子返回的信号(质荷比m/z)区分开来。 利用电喷射离子化作用产生的大量电荷,这种高分辨率同样也可以应用于蛋白质等高分子研究中。这些大分子中包含的同位素分布能够产生一系列同位素峰,由于这些同位素峰在质荷比坐标轴上十分接近,因此我们就要用到FTICR所具有的高解析分辨能力,结合大量电荷喷射来对其进行观察研究。 (zh)
name
  • Fourier transform ion cyclotron resonance (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/ICR_Cell.jpg
  • http://commons.wikimedia.org/wiki/Special:FilePath/LTQ-FTICR.jpg
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
thumbnail
caption
  • A FTMS instrument at the Pacific Northwest National Laboratory, USA (en)
classification
related
has abstract
  • Die FT-ICR-Massenspektrometrie (FT-ICR-MS = Fourier-Transform Ionenzyklotronresonanz Massenspektrometrie) ist ein Verfahren der Ionenfallen-Massenspektrometrie mit sehr hoher Massenauflösung. (de)
  • Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (m/z) of ions based on the cyclotron frequency of the ions in a fixed magnetic field. The ions are trapped in a Penning trap (a magnetic field with electric trapping plates), where they are excited (at their resonant cyclotron frequencies) to a larger cyclotron radius by an oscillating electric field orthogonal to the magnetic field. After the excitation field is removed, the ions are rotating at their cyclotron frequency in phase (as a "packet" of ions). These ions induce a charge (detected as an image current) on a pair of electrodes as the packets of ions pass close to them. The resulting signal is called a free induction decay (FID), transient or interferogram that consists of a superposition of sine waves. The useful signal is extracted from this data by performing a Fourier transform to give a mass spectrum. (en)
  • La espectrometría de masas por resonancia de ciclotrón iónica por transformada de Fourier (FT-ICR por sus siglas en inglés) es un tipo de analizador de masas (o espectrómetro de masas) para determinar la relación masa-carga (m/z) de iones en función de la frecuencia de ciclotrón de los iones en un campo magnético fijo.​ Los iones están atrapados en una trampa Penning (un campo magnético con placas de captura eléctricas), donde son excitados (en sus frecuencias de ciclotrón resonantes) a un radio de ciclotrón más grande por un campo eléctrico oscilante ortogonal al campo magnético. Después de que se elimina el campo de excitación, los iones giran en su frecuencia de ciclotrón en fase (como un "paquete" de iones). Estos iones inducen una carga (detectada como una corriente de imagen) en un par de electrodos a medida que los paquetes de iones pasan cerca de ellos. La señal resultante se llama (FID), transitoria o interferograma que consiste en una superposición de ondas sinusoidales. La señal útil se extrae de estos datos realizando una transformación de Fourier para dar un espectro de masas. (es)
  • La spectrométrie de masse à résonance cyclotronique ionique (FT-ICR-MS) est un instrument possédant un haut pouvoir de résolution et une bonne exactitude sur la masse très important pour l’analyse des protéines. C’est une technique basée sur le piégeage et l’excitation des ions dans une cellule ICR (résonance cyclotronique des ions) sous l’action d’un champ électromagnétique. Le spectre de masse est obtenu via la transformée de Fourier qui convertit le signal temporel acquis en spectre de fréquence proportionnel à la masse. FT-ICR-MS a été développée pour la première fois par Comisarow et Marshall en 1974, et l’utilisation du principe d’ICR dans un spectre de masse par Sommer. Cette technique d’analyse est très appliquée dans le domaine pharmaceutique, biologique par exemple pour l’identification des protéines. (fr)
  • In spettrometria di massa l'analizzatore a risonanza ionica ciclotronica a trasformata di Fourier è un analizzatore basato sul fatto che uno ione eccitato con radiofrequenze emette energia. Richiede un vuoto spinto, dell'ordine di 10-9-10-10 Torr. È un analizzatore non distruttivo, ha risoluzione fino a 1.000.000. Si indica comunemente come FT-ICR, acronimo dell'inglese Fourier transform-ion cyclotron resonance. (it)
  • フーリエ変換イオンサイクロトロン共鳴質量分析計(Fourier Transfom Ion Cyclotron Resonance Mass Spectrometer;FT-ICR-MS)とは、質量分析計の形式の一つ。 (ja)
  • Analizator cyklotronowego rezonansu jonów z fourierowską transformacją wyników (Fourier Transform Ion Cyclotron Resonance, FT-ICR) – analizator stosunku masy do ładunku elektrycznego jonów, jest głównym elementem konstrukcji niektórych spektrometrów mas. Analizator zbudowany jest w oparciu o pułapkę jonową. Jony wstrzyknięte do pułapki poruszają się w polu magnetycznym. W pierwszej fazie jony są wzbudzone (przyspieszane) zmiennym polem elektrycznym, wzbudzeniu ulegają tylko jony będące w rezonansie cyklotronowym z pobudzającym je polem. Po wzbudzeniu jony krążą w polu magnetycznym jako „pakiet” jonów. Krążący pakiet jonów indukuje napięcie elektryczne w elektrodach detekcyjnych. Indukowany sygnał rejestruje się, jako zależność napięcia od czasu. Poprzez wykonanie transformacji Fouriera zależność napięcia od czasu jest przekształcana na rozkład ilości jonów od stosunku masy do ładunku. Pomiar nie usuwa (zazwyczaj) badanych jonów z pułapki. W pułapce analizatora poprzez odpowiednie wzbudzanie można selekcjonować jony, usuwać wybrane jony, chłodzić jony. Analizatory FT-ICR są znacznie szybsze niż tradycyjne analizatory ICR. Inne parametry takie jak rozdzielczość, czułość, są podobne. Do przetwarzania sygnału z analizatora FT-ICR stosuje się komputery. Analizatory FT-ICR wyparły obecnie z rynku analizatory ICR. (pl)
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (61 GB total memory, 38 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software